USAfixTM - Repair Guide (RG) - Master Email RG
- Check Battery Cables
 Level of Difficulty - MEDIUM  Estimated Completion Time - 15 minutes
TASKI - COMBIMATSWINGO2500

Tools Required
Tool 
Wrench-Allen metric 6.0mm

Parts Required


Step Procedure & Parts & Tools
1 LOCATE THE DRAIN HOSES ON THE BACK OF THE MACHINE

2 PULL TO REMOVE THE BLUE CAPPED HOSE FROM MACHINE. PLACE HOSE NEAR DRAIN AND REMOVE CAP

3 PULL TO REMOVE THE RED CAPPED HOSE FROM MACHINE. PLACE HOSE NEAR DRAIN AND REMOVE CAP

4 LOCATE THE 2 BOLTS AT THE FRONT BASE OF MACHINE. REMOVE THE 2 BOLTS ON EACH SIDE OF BASE (SET BOLTS ASIDE)
Wrench-Allen metric 6.0mm

5 LIFT THE FRONT OF THE TANK TO OPEN THE MACHINE AND LOCATE THE BATTERIES

6 VISUALLY INSPECT THE BATTERY CABLES FOR CONNECTIVITY, CORROSION AND DAMAGE

7 CLOSE THE MACHINE AND REINSTALL THE TANK BOLTS IF CABLES ARE OK. FILL THE SOLUTION TANK IF NEEDED
Wrench-Allen metric 6.0mm