Step | | Procedure & Parts & Tools |
1 |
|
TURN THE COVER AND LIFT UP TO REMOVE IT.
|
2 |
|
LIFT THE SEAT UP TO ACCESS THE VACUUM COVER.
|
3 |
|
LIFT UP ON THE VACUUM COVER TO REMOVE IT.
|
4 |
|
TURN THE KEY TO POWER THE MACHINE ON.
|
5 |
|
PUSH THE SOLUTION BUTTON TO TURN ON THE PUMP.
|
6 |
|
LOCATE THE WHITE CONNECTOR BLOCK NEXT TO THE PUMP. INSERT THE VOLT METER PROBES INTO THE RED AND BLACK WIRE HOLDERS. TURN THE VOLT METER TO VOLTAGE. THE VOLT METER SHOULD READ APPROX. 24 VOLTS.
Volt meter (True RMS capable) |
|
|
7 |
|
IF THE SOLUTION PUMP IS GETTING POWER, CONTINUE TROUBLESHOOTING.
|