Step | | Procedure & Parts & Tools |
1 |
|
Using a Phillips screwdriver, remove the 3 screws from the floor of the machine.
Screwdriver-phillips |
|
|
2 |
|
Lift up on the floor of the machine to remove.
|
3 |
|
Locate the potentiometer, and using a 3mm Allen wrench, turn the set screw.
Wrench-Allen metric 3.0mm |
|
|
4 |
|
Pull the traction plug from the control board.
|
5 |
|
Connect the volt meter to the control board where you removed the traction wire. Continue to adjust the set screw until the volt meter reads 0. When it reads 0, that is neutral.