USAfixTM - Repair Guide (RG) - Master Email RG
- Test the drive motor
 Level of Difficulty - HIGH  Estimated Completion Time - 5 minutes
TENNANT - 2550

Tools Required
Tool 
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 PUSH THE BUTTON ON THE TOP PANEL TO POWER MACHINE.

2 CONNECT THE VOLT METER PROBES TO THE DRIVE MOTOR WIRES LOCATED AT THE BACK, BOTTOM OF THE MACHINE.
Volt meter (True RMS capable)

3 TURN ONE OF THE HANDLES ALL THE WAY FORWARD. THE VOLT METER SHOULD READ 36 VOLTS.
Volt meter (True RMS capable)