USAfixTM - Repair Guide (RG) - Master Email RG
- Replace Battery
 Level of Difficulty - MEDIUM  Estimated Completion Time - 15 minutes
MINUTE - M-220021K17C

Tools Required
Tool 
Ratchet-Socket metric 10mm
Wrench-Allen standard 3/16 in
Wrench-metric 10mm

Parts Required
PartDescriptionPriceAvailablePurchase
162-0006 12V 18Ah AGM battery (size 6) $97.75 Back Order Qty:


Step Procedure & Parts & Tools
1 DISCONNECT ANDERSON PLUG

2 LOOSEN BOTTOM BOLT AND NUT AND REMOVE TOP BOLT AND NUT
Wrench-Allen standard 3/16 in
Wrench-metric 10mm

3 SLIDE BATTERY BOX AWAY FROM FRAME

4 PULL TO REMOVE THE BATTERY
Wrench-metric 10mm

5 LOOSEN BOTH NUTS TO REMOVE TERMINAL CONNECTOR FROM BATTERY
Wrench-metric 10mm

6 LIFT CONNECTOR FROM BATTERY POST

7 REVERSE STEPS 1 THRU 6 TO REPLACE WITH A NEW BATTERY
Ratchet-Socket metric 10mm
Wrench-Allen standard 3/16 in

PartDescriptionPriceQty
162-0006 12V 18Ah AGM battery (size 6) $97.75 Qty: